Single-phase asynchronous motor: connection diagram with starting winding and capacitor starting - what is the difference and how to implement them in practice


The manufacture of homemade machines and mechanisms requires a torque source capable of developing high mechanical power on the drive shaft when powered from a 220-volt network.

An electric motor from a concrete mixer, washing machine, other equipment, or simply purchased on sale is suitable for these purposes.

In the article I tell you everything about a single-phase asynchronous motor, the connection diagram of which depends on the internal design and can be made with a starting winding or capacitor starting.

  • What should be taken into account in the design of stator windings and how to prepare them
  • How to distinguish the design of a single-phase asynchronous electric motor and determine its type using a statistical table
  • Connection diagram for an asynchronous motor with a starting winding: assembly sequence
  • Wiring diagram for an asynchronous motor with capacitor start: 3 technologies
  • How to change the direction of rotation of a single-phase asynchronous motor: 2 schemes
  • Where you should definitely start connecting the engine: 2 important time-tested points

    Before turning on any electric motor for the first time, it is necessary to clarify its structure: the design of the stator and rotor, the condition of the bearings.

    Single-phase electric motor design

    From my own and other people’s experience, I can assure you that it is easier to loosen a few nuts, inspect the internal structure, identify defects at the initial stage and eliminate them, than to deal with complex repairs that could have been prevented after starting a short operation.

    Important Warning

    Novice electricians quite often create engine malfunctions themselves, violating the technology for disassembling it, working with an ordinary hammer: they break the edges of the shaft.

    To preserve the structure of parts without damaging them, it is necessary to use a special electric motor bearing puller.

    Motor Bearing Puller

    In the most extreme case, when it is not available, blows with a hammer are applied through thick plates of soft metal (copper, aluminum) or dense dry wood (apple tree, pear tree, oak).

    How bearing condition affects engine performance

    Any asynchronous electric motor (IM) has a rotor with squirrel-cage windings. A current is induced in them, creating a magnetic flux that interacts with the rotating magnetic field of the stator, which is its source of movement.

    The rotor inside the housing is mounted on bearings. Their condition greatly affects the quality of rotation. They are designed to ensure easy sliding of the shaft without backlash or runout. Any violations are unacceptable.

    The fact is that the stator winding can be considered as an ordinary electromagnet. If the rotor's bearings are broken, then under the influence of the magnetic field it will begin to be attracted, approaching the stator winding.

    The gap between the rotating and stationary parts is very small. Therefore, touching or beating the rotor can touch, scratch, or deform the stator windings, irreversibly damaging them. The repair will require a complete rewinding of the stator, and this is a very difficult job.

    Be sure to disassemble the electric motor before connecting it, and carefully inspect its entire internal structure.

    Pay special attention to the condition of the bearings, compliance with tolerances and fits, and quality of lubrication. Dry and old lubricant must be replaced with fresh one.

    What should be taken into account in the design of stator windings and how to prepare them

    The home mechanic most often comes across electric motors that have already been used somewhere, and, perhaps, have undergone reconstruction or rewinding. Nobody usually declares this, the information on nameplates and tags is not changed, it is left the same. Therefore, I recommend visually inspecting their insides.

    Stator coils for asynchronous motors for power supply from single-phase and three-phase networks differ in the number of windings and design.

    A three-phase electric motor has three absolutely identical windings, spaced apart in the direction of rotation of the rotor by 120 angular degrees. They are made of one wire with the same number of turns.

    They all have equal active and inductive resistance and occupy the same number of slots inside the stator.

    This allows you to initially assess their condition with a conventional digital multimeter in ohmmeter mode with the voltage turned off.

    A single-phase induction motor has two different windings on the stator, separated by 90 angular degrees. One of them is designed for long-term passage of current in the nominal operating mode and is therefore called the main, main or working.

    To reduce heating, it is made with a thicker wire that has lower electrical resistance.

    A second winding of greater resistance and smaller diameter is mounted perpendicular to it, which makes it possible to distinguish it visually. It is designed for short-term flow of starting currents and turns off immediately when the rotor reaches the rated speed.

    The starting or auxiliary winding occupies approximately 1/3 of the stator slots, and the rest is allocated to the working turns.

    However, this rule has exceptions: in practice, there are single-phase electric motors with two identical windings.

    To connect the stator to the power supply, the ends of the windings are brought out with wires. Taking into account the fact that one winding has two ends, a three-phase electric motor can, as a rule, have six terminals, and a single-phase motor can have four.

    But there are exceptions to this simple rule related to internal switching of pins to simplify installation on special equipment:

    • for three-phase motors, the following can be removed from the stator: three wires when internally assembling a delta circuit;
    • or four - for a star;
  • a single-phase electric motor can have:
      three outputs with internal combination of one end of the starting and working windings;
    • or six ends for a design with a starting winding and a built-in contact for disconnecting it from the centrifugal regulator.

    As you can see, it is possible to judge the design of an asynchronous motor by the number of wires connected to the terminal block from the stator windings, but the probability of error is quite high. A more thorough analysis of its structure is needed.

    Technical condition of winding insulation

    Where and under what conditions the stator was stored is not always known. If it was unprotected from precipitation or inside wet rooms, then its insulation requires drying.

    At home, the disassembled stator can be placed in a dry room to dry. It is possible to speed up the process by blowing a fan or heating with conventional incandescent lamps.

    Drying the electric motor

    Make sure that the heated glass of the lamp does not touch the winding wire; ensure an air gap. The end of the drying process is associated with the restoration of the insulation properties. This process must be controlled by measurements with a megohmmeter.

    Single-phase and three-phase asynchronous motors

    We agreed - three-phase commutator motors are difficult to obtain; the current section concerns asynchronous machines. We list the varieties:

    1. Three-phase asynchronous motors are equipped with a number of outputs from three to six working windings minus various fuses, internal relays, and various sensors. The stator coils inside are connected by a star, making it impossible to directly connect to a single-phase network.
    2. Single-phase motors equipped with a starting winding are, among other things, equipped with a pair of contacts leading to a centrifugal limit switch. The miniature device breaks the chain when the shaft is untwisted. The starting winding catalyzes the initial stage. Further action will interfere, reducing the efficiency of the engine. The design is usually called bifilar. The starting winding is wound with double wire, reducing reactance. Helps reduce the capacitance of the capacitor - critical. A striking example of single-phase asynchronous motors with a starting winding are the compressors of household refrigerators.
    3. The capacitor winding, different from the starting winding, operates continuously. We will find the motors inside the floor fans. The capacitor provides a phase shift of 90 degrees, allowing you to choose the direction of rotation and maintain the desired shape of the electromagnetic field inside the rotor. Typically the capacitor is mounted on the motor housing.

    Read also: 7805 Datasheet in Russian equivalent

    Starting a single-phase motor with a capacitor

    Three-phase asynchronous motors

    Let's learn how to distinguish single-phase asynchronous motors from three-phase ones. In the latter case, there are always three equal windings inside. Therefore, you can find three pairs of contacts that, when examined by a tester, give the same resistance. For example, 9 ohms. If the windings are connected by a star inside, there will be three terminals with the same resistance. Of these, any pair gives identical readings displayed on the multimeter screen. The resistance is equal to two windings each time.

    Because current must flow out, sometimes a three-phase motor has a neutral terminal. The center of the star, with each of the other three wires, gives identical resistance, half that shown by the pairwise continuity. The above symptoms speak eloquently: the motor is three-phase, alien to the topic of today’s conversation.

    The winding motors discussed in this section contain two. One starting or capacitor (auxiliary). There are usually three or four conclusions. If there is no capacitor decorating the case, you can try to reason, puzzled by the purpose of the contacts, as follows:

      There are four pins - you need to measure the resistance. Usually they ring in pairs. The resistance is lower - we found the main winding connected to a 230 volt network without a capacitor. Polarity does not matter; the direction of rotation is set by the way the auxiliary winding is turned on, by switching the coils. Simply put, connect a single-phase electric motor of a characteristic type with only one main winding - in the initial period of time the shaft stands upright. Wherever you spin, there will be rotation. Beware of starting with your hand - it will break.

    Starting a single-phase motor with a capacitor

    Asynchronous motor device

    Connection diagram for an asynchronous motor with a starting winding: assembly sequence

    For example, we have determined that there are four or three wires coming out of the stator. We call up the active resistance between them with an ohmmeter and determine the starting and operating windings.

    Let’s assume that four wires have two pairs with resistances of 6 and 12 ohms connected to each other. Let's randomly twist one wire from each winding, designate this place as a “common wire” and get a measurement of 6, 12, 18 Ohms between the three terminals.

    Motor winding resistance

    I marked the beginnings of the windings with dots on this diagram. For now, ignore this question. But, you will need to return to it further when the need arises to reverse.

    The chain between the common terminal and the lower resistance 6Ω will be the main one, and the larger 12Ω will be the auxiliary, starting winding. Connecting them in series will show a total result of 18 ohms.

    We mark these 3 ends with markings that are already clear to us:

    • O - general;
    • P - starting;
    • R - worker.

    Next we need a PNVS button, specially designed for starting single-phase asynchronous motors. Its electrical circuit is represented by three closing contacts.

    But, it has an important difference from the start button of three-phase NVD electric motors: its middle contact is made with self-return, and not fixed when pressed.

    PNVA button diagram

    This means that when the button is pressed, all three contacts are closed and held in that position. But, when you release your hand, the two outer contacts remain closed, and the middle one returns under the action of the spring to the open state.

    NVS button

    We connect this button and the terminals for the output of the stator windings from the electric motor with a three-core cable so that the starting winding contact goes to the middle contact of the PNVS. We connect pins P and P to its outermost contacts and mark them.

    On the back side of the button, between the contacts of the starting and working windings, we rigidly mount a jumper. We connect a 220 volt household power cable with a plug for installation in a socket to it and the second outer contact.

    Connection diagram for an asynchronous motor with a starting capacitor

    When this button is turned on, all three contacts will close, and the working and starting windings will begin to work. In just a couple of seconds the engine will finish accelerating and return to nominal mode.

    Then the start button is released:

    • the starting winding is switched off by self-return of the middle contact;
    • the main winding of the motor continues to spin the rotor from a 220 V network.

    This is the most affordable connection diagram for an asynchronous motor with a starting winding for the home craftsman. However, it requires the presence of a ventilator button.

    If it is not there, and the electric motor urgently needs to be started, then it can be replaced with a combination of a two-pole circuit breaker and a conventional electric button of the appropriate power with self-reset.

    You will have to turn them on at the same time, and release the button after spinning up the electric motor.

    Always perform all starts of electric motors and any electrical equipment with the protection of these circuits by circuit breakers. They will prevent the development of emergency situations when any random errors occur.

    In order to consolidate the material on this topic, I recommend watching the video of the owner Oleg pl. It just shows the design of a built-in centrifugal regulator designed to automatically turn off the auxiliary winding.

    Features of using a magnetic starter

    The control part of the device has several pairs of contacts on which the relay automation circuit is assembled. One of them is always normally closed, and the second is always normally open.

    The “Start” button has a normally open contact, while the “Stop” button has a normally closed element.

    When connecting the device in question, several types of connections are made.

    Starting a single-phase motor with a capacitor

    Single-phase motor connection diagram

    The phase, along with the input terminal, is also connected to the contact input of the “Stop” button, and the zero is connected to the input terminal of the coil, which ensures that control current flows through it.

    The active contact of the “Start” button when the engine is running is bypassed by a similar element of the coil. To form this circuit, two additional connections are made, the diagram of which is shown in the figure above:

    • the output of the working contact of the “Stop” button is connected in parallel with the output contacts of the “Start” button and the input of the control coil;
    • the output of the normally open contact of the control coil is connected in parallel to its output terminal and to the input of the working contact of the “Start” button.

    Wiring diagram for an asynchronous motor with capacitor start: 3 technologies

    The stator with windings for starting from capacitors has approximately the same design as discussed above. It is difficult to distinguish it by appearance and simple measurements with a multimeter, although the windings may have equal resistance.

    Refer to the nameplate and table from Aliyev’s book. You can try to connect such an electric motor using a circuit with a PNVS button, but it will not spin up.

    It will not have enough starting torque from the auxiliary winding. It will hum and twitch, but will not reach the rotation mode. Here you need to assemble a different capacitor starting circuit.

    The 2 ends of different windings are connected to a common terminal O. A household voltage of 220 volts is supplied to it and the second end of the working winding through an AB switching device.

    The capacitor is connected to the terminals of the starting and operating windings.

    As a switching device, you can use a double circuit breaker, a switch, NVD or NVDS type buttons.

    Wiring diagram for an asynchronous motor with capacitor start

    Here it turns out that:

    • the main winding operates directly from 220 V;
    • auxiliary - only through the capacitor.

    This circuit is used for easy starting of capacitor electric motors that are put into operation without heavy load on the drive, for example, fans, sanders.

    If, at the moment of starting, it is necessary to simultaneously spin the belt drive, gear mechanism of the gearbox or other heavy drive, then a starting capacitor is added to the circuit, which increases the starting torque.

    It is convenient to describe the operating principle of such a scheme using the same PVS button.

    Connection diagram for an asynchronous motor with a starting capacitor PNVS

    Its self-resetting contact is connected to the auxiliary winding through an additional starting capacitor Sp. The second end of its plate is connected to terminal P and working capacity Cp.

    An additional capacitor at the moment of starting an electric motor with a heavy drive helps it quickly reach its rated rotation speed, and then simply turns off so as not to create overheating of the stator.

    This circuit is fraught with one danger associated with long-term storage of a capacitive charge by the starting capacitor after removing power 220 when the electric motor is turned off.

    If the worker is not careful or careless, the discharge current can pass through the human body. Therefore, the charged capacity must be discharged.

    In the scheme under consideration, after removing the voltage and pulling out the plug and power cord from the socket, this can be done by briefly turning on the PVS button. Then the capacitance Sp will begin to discharge through the starting winding of the motor.

    However, not all people do this for various reasons. Therefore, it is recommended to install two additional resistors in the starting circuit.

    Connection diagram for an asynchronous motor via capacitors

    Resistance Rр is selected with a nominal value of about 300÷500 Ohms of several watts. Its task is to discharge the auxiliary capacitance Sp after removing the supply voltage.

    The Ro resistor is low-resistance and powerful and acts as a current-limiting resistance.

    Adding resistors to the electric motor starting circuit increases the safety of its operation and automatically limits the flow of capacitive discharge current of a charged capacitor through the human body.

    Where can I get the values ​​of the main and auxiliary capacitors?

    The fact is that the factory determines the value of the starting and operating capacitance for capacitor starting of a single-phase IM individually for each model and indicates this value in the passport.

    There are simply no separate formulas for calculating how it is done for capacitor starting of a three-phase motor in a single-phase network using star or delta circuits.

    You will need to look for factory recommendations or experiment during the setup process with different containers, choosing the most optimal option.

    The owner of the video “IV I'm Interested” shows how to optimally configure the parameters of a capacitor motor starting circuit.

    Rating
    ( 2 ratings, average 4.5 out of 5 )
    Did you like the article? Share with friends: